Whole Room Water Cooling Part 7 - It's FINALLY over!

Linus Tech Tips ·Linus Tech Tips ·2016-05-06 · 2,039 words · ~10 min read
Floatplane YouTube

Transcript

JSON SRT VTT 154
0:00 karen's graphics card was running at like 100 degrees idle while water cooled
0:04 but the water still has to run through this
0:08 graphics card and see how terrible it is can you see the floater right there
0:12 it moves around if you tip the card
0:15 the metal touched my skin but the problem that i have right now is
0:21 the plan was to just remove the graphics card from the loop put another graphics
0:25 card in there and then have the loop go through this non-powered graphics card
0:30 which would hopefully not add any temperature to the loop and then it would be fine but i don't even want to
0:34 run this computer on the full loop if it's this gunked up
0:45 Corsair delivers real mech or oh here i have one huh real mac or nothing with
0:50 their new strafe mechanical keyboard featuring genuine german-made cherry mx
0:53 key switches click on manchin to learn
0:56 more i'm gonna move my chin now just a three for a loop
1:00 at last my friends it is finally
1:03 finally here the conclusion of the whole
1:07 room water cooling system series of videos that we have waited
1:12 over a year since initially putting
1:15 these systems together to finally talk about whether or not the concept worked
1:21 whether or not in practice it actually worked and the wait is over only a
1:26 couple more minutes it kind of reminds me of that uh that bmw video that i was
1:30 teasing on social media not that long ago about the all-new one series drop a
1:33 like on the bottom of the video if you want to see us finally release that because i think we're very close
1:38 let's go so i want to do a recap of the concept for those who haven't been
1:43 following along the whole time our editing den is in a south-facing room of
1:48 the house that we have been running Linus media group out of for the last
1:51 year and a half and it gets
1:55 friggin hot in here so my brilliant idea was
1:58 what if we took all of our editing workstations and removed the heat from
2:02 the room via water cooling so it started
2:05 with redoing our editing workstations which used to be just a haphazard mix of
2:09 parts that we had left over from reviews and are now pretty much all standardized
2:13 so they've got n600 cases from cooler master water cooling by swift tech and
2:17 i'll explain why there's a radiator on the outside of the system in spite of
2:21 the whole room water cooling i'll explain that later
2:24 we've got 4960x six core processors those are extreme editions 32 gigs of
2:29 kingston memory ASUS x99 deluxe motherboards gtx titan blacks so those
2:35 are six gig vram cards we've also got cooler master v750 power supplies and
2:40 all of them except exiles which actually has two of these a quadro a 10 gigabit
2:44 nick and then a v 1200 because uh his system is kind of balls to the wall and
2:48 then each system has its own pump as well so the way that it all works is
2:53 that at the back we've got kind of a a tangle of of tubing going on here so
2:59 we've got quick release fittings here so we can either
3:03 connect to the radiator on the top which is running quite toasty right now or
3:08 to the whole room system and this was actually all done up by luke's dad who
3:13 did an amazing job of plumbing the
3:16 entire room for us so you can see the terminus station is actually over here
3:23 by nick van berkel's pc so every one of these systems has an inlet and then an
3:28 outlet and they all join together as you go around the room we actually left
3:32 enough space to have up to seven systems water cooled all at the same
3:38 time all on the same loop and in the
3:41 bathroom server room this is where the magic
3:44 happens so here's our mechanical and then uh uv sterilizing filters here is
3:50 our reservoir here are our dual little giant pumps and then those lead to a
3:56 radiator fan setup using Noctua industrial ppc fans so those waterproof
4:02 dust proof ones on the roof of the house
4:05 so that we are actually physically removing the heat from the building in
4:11 order to keep our systems cool we've got a cover on there we've got a power
4:15 supply for all of the fans to run as well
4:18 so with that recapped how does it
4:22 perform so to evaluate our success there's a number of different metrics to
4:26 look at we can look at the cooling performance of the individual systems
4:31 based on how hot their cpus run during an intensive task like video rendering
4:37 we can look at the room temperature inside versus the temperature outside to
4:42 see if removing the heat from the room actually yielded any kind of benefit and
4:48 we can look at the convenience and maintenance factors so let's start with
4:53 CPU temperatures when we're running the
4:56 cpus on their own radiators the room
5:00 reaches a temperature of about 31 degrees so you can actually see that
5:04 right now which is about a three degree difference between the inside and the
5:09 outside and you should bear in mind that that's on a day that's not particularly
5:13 sunny which can cause the room to heat up quite a bit more than the computers
5:17 could possibly affect all the systems
5:20 and the sort of 45 degree plus range on
5:24 the CPU which is reasonable except for terrans which i'll talk more about later
5:30 and edsels which has an additional graphics card but no additional radiator
5:34 space for cooling so that one's bound to run a little bit on the hotter side so
5:40 now what we're gonna do is we are going to take the running whole room system
5:44 i'll show you guys how we quickly connect and disconnect them
5:49 so while they're running probably not recommended but we've done it so many
5:53 times anyway that it i've lost all fear of the process
5:58 all we do is use these to hook it up
6:03 to the whole room system now
6:07 what you are likely to see here is a nearly instantaneous drop
6:14 in CPU temperatures so we've gone from 47 on core 1 to 41
6:20 and i'll make some graphs here showing you guys the difference in CPU temps
6:24 under load from system to system to dramatically reduce temperatures across
6:29 the board by hooking up to the whole room system why does that work well it's just a
6:35 matter of radiator capacity we could just as easily achieve great CPU
6:39 temperatures by hooking up much much larger radiators as you'll see in some
6:44 very large towers this will support like quad rads in the front duals in the top
6:48 a single in the back and the like another advantage of this approach by
6:53 having it outside is that you don't end up with a chain reaction of the room
6:58 temperature increasing and therefore the cooling efficiency of your radiator
7:02 increasing because you're always tied to ambient temperatures but
7:06 that's a great question if one of the objectives was to lower the ambient
7:09 temperature in the room with this system how much have you achieved the answer is
7:14 not a heck of a lot we achieved a one degree drop by hooking all of these
7:18 systems up which i would consider within the sort of margin of error the sort of
7:24 a vague sort of concept so being able to align this correctly helps a lot
7:29 on our inlet so that's the cold side we're getting 29.7 degrees
7:35 and on our outlet that's the hot side
7:39 we are getting 30.0 degrees which i'm sure someone out
7:43 there is calculating the specific heat of this you know mass of water or
7:49 whatever the case may be and i'm sure that we are actually dissipating a
7:52 significant amount of the heat outside but that is where the whole
7:56 was it actually practical thing comes into play because by going with copper
8:01 tubing which i think we can all agree is more aesthetically pleasing than
8:05 insulated pvc we actually created a situation where we are dissipating a
8:10 significant amount of the heat we're pulling out of each system
8:15 into the room anyway anyway via the copper piping
8:21 so i guess all that's really left now is
8:24 do we consider the project a success the answer is no um i still think the
8:29 concept could have worked really well but there were a few critical things
8:34 that i really think we could have done differently number one don't use a metal
8:38 reservoir don't use a metal reservoir
8:42 find some kind of plastic reservoir to use because that's where the thing that
8:47 i promised to talk about later comes in terran system has some big problems
8:52 caused by corrosion bits stuck in his system that even cleaning out his CPU
8:58 block which was extremely gunked up that was a picture i posted on instagram
9:02 could not fix and um
9:06 point number two is i would definitely recommend installing some kind of a
9:10 bleed system at the highest point in the loop that way you are not going to have
9:14 as much difficulty filling the system each time uh compared to
9:19 us where we had to add a second pump in order to have enough flow rate and
9:23 enough pressure in order to get the water in and the air out of our tubing
9:28 system uh the other thing that i would do differently next time is um
9:33 wow gee i guess that ties into a question that we've been asked a lot
9:37 aren't you guys moving why did you bother with all of this and are you
9:40 gonna do whole room water cooling at the new place well number one we weren't
9:43 planning to move when we originally came up with this concept and started working
9:47 on it so there's that uh number two no we do not
9:52 intend to water cool our systems let alone whole room water cool our systems
9:57 at the new office we're gonna have air conditioning which is probably the
10:01 solution that we should have gone with in the first place if the objective was
10:05 to lower the temperature in this room
10:09 and have our computers run cooler
10:13 so i think that's pretty much it thank you guys for sticking with us throughout the
10:18 whole room water cooling project we learned a lot i think we established the
10:23 feasibility of it the performance and the silence factor cannot be denied but
10:30 the convenience factor of it leaves a lot to be desired and the
10:36 the execution of it would be extraordinarily time consuming and even
10:40 more expensive than what we did if you were to really do it properly in such a
10:46 way that it would require little or zero maintenance over the long
10:50 run thanks for watching guys uh if you
10:54 disliked this video i think you know what to do but if you liked it and if
10:57 you appreciated the whole series then do please press that like button also
11:02 consider checking out all the other things you can do to support us like buy
11:05 a cool t-shirt like this one you can change your amazon bookmarks one
11:09 with our affiliate code you can support us directly through the forum if you're
11:12 done doing all that stuff and you're looking for something fun to watch we
11:16 actually just did an update to our new office vlog series so that's where we're
11:22 doing everything properly we're not working out of a house anymore so do
11:25 feel free to go check that out and thanks again for watching i'll see you
11:29 guys on the other side