now every gamer knows you should use a highquality power supply with your

00:00:10.679 --> 00:00:17.560
gaming PC it delivers better efficiency it delivers more a more quiet experience

00:00:16.199 --> 00:00:21.960
and it also gives you peace of mind because your valuable components that

00:00:19.520 --> 00:00:26.720
you have hooked up to it are less likely to die in a fiery power supply explosion

00:00:25.199 --> 00:00:31.320
which no okay they don't actually explode that often but what you can have

00:00:29.240 --> 00:00:34.800
in a catastrophic power supply failure is a power surge that fries other

00:00:33.200 --> 00:00:39.520
components in your system it's less common these days especially with high

00:00:36.520 --> 00:00:42.800
quality units like this particular one

00:00:39.520 --> 00:00:44.520
but what a lot of users don't consider

00:00:42.800 --> 00:00:49.000
is what kind of power you're actually feeding into your power supply so here

00:00:46.719 --> 00:00:53.640
we have what's called a UPS or an uninterruptible power supply this one's

00:00:50.760 --> 00:00:57.079
from cyber power and it is capable of a couple of things so number one is that

00:00:55.480 --> 00:01:01.079
it is line interactive which means that it is

00:00:59.600 --> 00:01:05.280
actually regulating and monitoring and cleaning

00:01:03.680 --> 00:01:10.439
the power that you are I can open the box uh the power that

00:01:08.400 --> 00:01:13.960
you are actually feeding into the power supply that is then powering your

00:01:12.000 --> 00:01:18.159
computer so it means there's less strain on your power supply less chance of

00:01:15.560 --> 00:01:21.799
failure and an overall more stable Computing experience people will say who

00:01:20.320 --> 00:01:28.040
I live in the first world my power is really good no no no no no no no no no

00:01:24.880 --> 00:01:30.759
even new buildings even in the first

00:01:28.040 --> 00:01:35.759
world even Wherever You Are no matter what you can have dirty AC power so that

00:01:33.920 --> 00:01:40.600
means whether it's little spikes or little dips uh sometimes the dips are

00:01:38.240 --> 00:01:45.520
experienced as what's called a brown out where uh you'll see the lights dim a

00:01:42.759 --> 00:01:51.320
little bit so yes these problems do exist and they are important a UPS

00:01:48.880 --> 00:01:57.799
also it's really heavy cuz it's full of lead batteries um a UPS

00:01:54.320 --> 00:01:59.920
also will allow you to have time to save

00:01:57.799 --> 00:02:05.000
your work and shut down your computer directly in the event of a power failure

00:02:03.280 --> 00:02:08.800
so give me a second here guys and I'm just going to go down what cyber power

00:02:07.240 --> 00:02:12.440
has to say for themselves before I keep going any longer so Power Protection for

00:02:10.599 --> 00:02:16.040
computers and workstations that use active power factor correction so more

00:02:13.920 --> 00:02:19.400
on that in a moment green power ups energy saving Technology power panel UPS

00:02:18.160 --> 00:02:24.319
management software so that's the software you use to well manage the UPS

00:02:21.920 --> 00:02:27.360
multi-function LCD power status display so we're going to do a full NC Tech tips

00:02:26.120 --> 00:02:32.120
episode on this one so you'll see that on my ncxc channel automatic voltage

00:02:30.160 --> 00:02:36.560
regulation 10 surge protected Outlets five with battery backup so that is five

00:02:34.080 --> 00:02:39.599
surge protected five battery backup phone coax line protection three year

00:02:38.000 --> 00:02:43.480
warranty and connected equipment guarantee now that's really cool because

00:02:41.480 --> 00:02:47.080
they will actually even guarantee that the equipment you have connected to it

00:02:44.800 --> 00:02:51.830
is not going to explode so this guy right here is capable of sustaining up

00:02:48.760 --> 00:02:54.929
to 600 watts

00:02:55.200 --> 00:03:02.560
and there we go that means that assuming

00:02:59.440 --> 00:03:04.319
you have have a a PC computer actually

00:03:02.560 --> 00:03:07.400
hooked up to it we're going to test this with a high- powerered gaming PC so I'm

00:03:06.040 --> 00:03:11.159
not even going to bother telling you guys how long it claims to run the

00:03:09.680 --> 00:03:15.159
connected computer for we're actually going to test it with benchmarking

00:03:12.840 --> 00:03:19.080
software so it will run your computer and give you a chance to either using

00:03:17.159 --> 00:03:23.159
the USB interface automatically shut down your PC properly in the event of a

00:03:21.599 --> 00:03:27.560
power failure or give you a chance if you're actually in the middle of using it to turn it off correctly so that's

00:03:26.280 --> 00:03:31.720
good for your software it's good for your Hardware it's good for a lot of

00:03:29.439 --> 00:03:36.720
things so so far the benefits are a couple okay safely powering on and

00:03:34.120 --> 00:03:40.120
powering off your computer as well as the other thing that I said right

00:03:38.360 --> 00:03:46.439
protecting your computer from Dirty power now here's the catch most UPS's

00:03:44.200 --> 00:03:50.400
that are not extremely expensive are not pure sinewave UPS's so if I don't know

00:03:49.120 --> 00:03:56.640
if you guys know anything about AC current but it basically looks like this it goes in what's called a sine wave and

00:03:54.319 --> 00:04:00.959
120 volts is the difference between the dip and the peak so that's your 120 volt

00:03:59.400 --> 00:04:04.920
power or if you're in the EU or somewhere else where you have 240 volt

00:04:03.120 --> 00:04:10.680
power you just have a bigger a bigger sine wave okay so a non-peer sine wave

00:04:08.120 --> 00:04:14.040
UPS because these are using batteries okay they're using batteries inside here

00:04:12.200 --> 00:04:18.280
to deliver AC power batteries do not natively deliver AC power they deliver

00:04:15.799 --> 00:04:23.360
DC power so they have to kind of fake it so um less competitive modern you know I

00:04:22.079 --> 00:04:28.040
don't know what to call them but not as good UPS's will deliver current that

00:04:25.560 --> 00:04:33.039
looks like this where it actually has a square sine wave pattern now this is

00:04:30.639 --> 00:04:36.160
fine as an approximation of a sine wave if you're going to power a light bulb or

00:04:34.840 --> 00:04:41.039
if you're going to power something that is not a sensitive piece of electronic

00:04:37.960 --> 00:04:42.520
equipment in comes active power factor

00:04:41.039 --> 00:04:48.320
correction now I haven't actually looked for it on this power supply but I

00:04:44.080 --> 00:04:52.520
guarantee you anything that

00:04:48.320 --> 00:04:55.919
is over 80 plus bronze is going to have

00:04:52.520 --> 00:04:58.680
apfc pretty much and I'm sorry it's not

00:04:55.919 --> 00:05:02.479
on here but trust me it it it does it has active power factor correction

00:05:00.080 --> 00:05:06.919
almost any modern power supply that is a high quality power supply does that

00:05:04.759 --> 00:05:12.840
allows it to achieve better efficiency active power factor correction will not

00:05:09.360 --> 00:05:15.320
accept an ugly Square sine wave so if

00:05:12.840 --> 00:05:20.600
you don't have a peer sine wave ups and cyber power in this case has some very

00:05:17.960 --> 00:05:23.720
very low cost compared to other act uh compared to other peer sine wave models

00:05:22.400 --> 00:05:28.800
so if you don't have a peer sign wave UPS what can happen is your computer can

00:05:26.000 --> 00:05:34.840
just shut down outright as soon as it gets that Square pattern voltage input

00:05:32.759 --> 00:05:37.680
okay so okay we'll look at the unit a little bit here in the unboxing but the

00:05:36.039 --> 00:05:42.919
most important part of this video is guys subscribe to my NCC Channel

00:05:40.560 --> 00:05:47.479
ncom because we're going to show you guys this one versus a non-peer sine

00:05:45.199 --> 00:05:52.880
wave unit to show you what happens in the event of a power failure with either

00:05:49.919 --> 00:05:56.280
of these battery backup Solutions so we'll have a look at the unit itself

00:05:54.440 --> 00:06:00.000
really quickly here most of this has been like theoretical stuff so what do

00:05:58.199 --> 00:06:03.960
we got we got your display button we got your silence alarm button your control

00:06:01.759 --> 00:06:07.319
button LCD readout you got your power button all this is fairly

00:06:05.479 --> 00:06:10.919
straightforward on the top here we have some important notes about safety

00:06:09.199 --> 00:06:17.039
features and powering on and powering off and all that kind of good stuff here

00:06:13.400 --> 00:06:19.120
we've got some ventilation holes

00:06:17.039 --> 00:06:22.520
okay it's a lot more attractive than UPS's used to be risk of electric shock

00:06:21.360 --> 00:06:27.639
refer to the bottom of the unit for cautionary markings cool more cautionary

00:06:25.199 --> 00:06:31.919
markings neat uh something to be aware of with UPS's is that eventually the

00:06:29.720 --> 00:06:35.639
batteries inside uh will die and they can be replaced or you can get a new UPS

00:06:33.680 --> 00:06:39.880
or whatever but I still definitely recommend using them uh as it mentioned

00:06:37.599 --> 00:06:44.520
on the packaging there's coax protection as well as uh phone SL Network

00:06:42.280 --> 00:06:50.680
protection interesting building wiring fault indicator serial and USB

00:06:47.120 --> 00:06:54.319
interfaces as well as the here we go

00:06:50.680 --> 00:06:57.120
Surge and Battery Plus surge outlets on

00:06:54.319 --> 00:07:00.000
the back and a way to reset the breaker nice beefy power cord because if you're

00:06:58.599 --> 00:07:06.440
going to be powering any reasonable amount of equipment off of it you're going to need that so as mentioned

00:07:04.120 --> 00:07:12.560
before 600 wat unit stay tuned for the ncx tech tips and thank you for checking

00:07:09.120 --> 00:07:15.000
out my cyber power adaptive sinewave

00:07:12.560 --> 00:07:17.560
uninterruptible power supply unboxing don't forget to subscribe for more

00:07:16.039 --> 00:07:20.560
unboxings reviews and other computer videos