WEBVTT

00:00:00.199 --> 00:00:08.000
all right guys as promised I'm going to be doing a temperature and Acoustics

00:00:04.960 --> 00:00:09.320
comparison between the reference GeForce

00:00:08.000 --> 00:00:14.799
GTX 560ti and the assus direct cu2 GeForce

00:00:13.320 --> 00:00:21.080
GTX 560ti and since uh I had so many

00:00:18.520 --> 00:00:27.840
requests to also include it I will be including the MSI GTX 560 TI twin frozer

00:00:25.119 --> 00:00:32.800
2 version of this graphics card so this will be a three-way Roundup I'm going to

00:00:29.519 --> 00:00:35.000
be using fir Mark yes I know it is not a

00:00:32.800 --> 00:00:41.640
perfect temperature and load testing application for GeForce cards because

00:00:38.520 --> 00:00:43.879
they will all Throttle Down when running

00:00:41.640 --> 00:00:48.079
firmar it is a software patch that NVIDIA has implemented to keep users

00:00:46.000 --> 00:00:53.520
from burning out their cards however since we're comparing three like gpus

00:00:50.320 --> 00:00:55.719
they're all GeForce GTX 560 TI my theory

00:00:53.520 --> 00:00:59.600
is that they'll all ramp down equally so we will at least be able to compare

00:00:58.120 --> 00:01:05.880
these three cards against each other both in terms of load temperatures as

00:01:02.120 --> 00:01:08.759
well as in terms of

00:01:05.880 --> 00:01:14.920
noise so for our stock reference cooled card we're looking at a load temps of

00:01:11.400 --> 00:01:17.320
about well not about exactly 75° C once

00:01:14.920 --> 00:01:23.600
it levels out since our room temperature is about 24° C we're going to round that

00:01:20.200 --> 00:01:27.799
up that means we have a Delta of

00:01:23.600 --> 00:01:30.000
51° C so I'll do all the audio clips uh

00:01:27.799 --> 00:01:34.439
at the end but uh just to show you guys how loud they are but the stock fan

00:01:32.399 --> 00:01:38.439
actually doesn't ramp up very high in terms of the overall fan speed so it

00:01:36.799 --> 00:01:44.920
remains fairly quiet now the direct cu2 is

00:01:41.680 --> 00:01:46.640
significantly louder than the stock fan

00:01:44.920 --> 00:01:53.880
but I think a big part of that is because the fan ramps right up to about

00:01:49.600 --> 00:01:57.320
2400 RPM but the good news is that with

00:01:53.880 --> 00:01:58.880
its hybrid of like a straight heat sink

00:01:57.320 --> 00:02:02.920
and then you see those heat pipes coming out there and and like a fin heat pipe

00:02:01.360 --> 00:02:09.039
design where the one fan is blowing at the heat sink and the other fan is blowing at the heat pipe fins they

00:02:06.719 --> 00:02:15.200
actually achieve significantly better temperatures than the stock cooler so at

00:02:12.000 --> 00:02:18.760
61° in a 24°

00:02:15.200 --> 00:02:21.200
room that is a Delta of only

00:02:18.760 --> 00:02:26.239
37° compared to the stock cooler which is significantly

00:02:23.760 --> 00:02:32.519
better all right so our room is closer to about the almost 27 so we'll call it

00:02:29.480 --> 00:02:34.720
uh 26° in our room right now it's gotten

00:02:32.519 --> 00:02:40.120
warm from doing uh from running fir mark on these video cards it's not a very

00:02:38.040 --> 00:02:44.599
large office that I have as you can plainly see all right so with the twin

00:02:42.760 --> 00:02:49.280
frozer 2 we're looking at LAD temperatures of

00:02:46.800 --> 00:02:57.080
50 okay we'll look over here load temperatures of 57° focus

00:02:54.640 --> 00:03:03.360
focus there we go 57° so when we take our room temp really

00:03:01.120 --> 00:03:09.640
wow it's going up really fast now so

00:03:05.480 --> 00:03:14.280
27° I will call it call it 26 cuz that's

00:03:09.640 --> 00:03:17.599
what it was before okay so 57us 26 gives

00:03:14.280 --> 00:03:19.280
us a 31 Dee Delta there it is yeah 26

00:03:17.599 --> 00:03:22.440
it's just air currents in the room right now so you guys got to understand that

00:03:21.080 --> 00:03:27.280
all of these results are only going to be accurate to within a couple degrees

00:03:24.480 --> 00:03:31.519
Delta because it's not a super controlled environment you can see my

00:03:28.720 --> 00:03:36.239
temp probe is uh generally positioned at the intake of the fans

00:03:33.840 --> 00:03:40.519
so yeah pretty much they're they're fairly equivalent I'd say in

00:03:37.920 --> 00:03:44.959
subjectively the noise from the Twin frozer 2 is pretty similar to the noise

00:03:42.519 --> 00:03:48.080
from the direct cu2 but I'll leave that for you guys to judge with the audio

00:03:46.760 --> 00:03:54.159
samples at the end don't forget to subscribe to Linus Tech tips for more unboxings reviews and other computer

00:03:51.159 --> 00:03:54.159
videos