WEBVTT

00:00:00.320 --> 00:00:08.840
this is an unboxing that I've been excited to do for a while this is an LSI

00:00:04.600 --> 00:00:11.599
Mega raid SAS 926 8i RAID controller

00:00:08.840 --> 00:00:17.199
card so this is exciting because it is a 6 gbit per second 8port SAS and SATA

00:00:15.080 --> 00:00:24.039
RAID card so what that means is you've actually got full support for either SAS

00:00:20.359 --> 00:00:26.160
or SATA drives and either 3 GB per

00:00:24.039 --> 00:00:30.599
second or 6 gbit per second so it's one of the most flexible raid cards out

00:00:28.080 --> 00:00:34.600
there today now the difference between SAS and SATA I've actually been asked

00:00:32.360 --> 00:00:40.320
this before SAS are basically Enterprise level drives and SATA are consumer level

00:00:36.559 --> 00:00:42.879
drives you can run a SATA drive on a SAS

00:00:40.320 --> 00:00:47.760
interface card but you cannot run a SAS drive on a SATA interface like what you

00:00:45.320 --> 00:00:51.640
would find built into a motherboard so there that is the difference here we're

00:00:49.600 --> 00:00:55.120
going to find the product specifications in brief so I'm going to go ahead and

00:00:53.120 --> 00:00:59.519
scan these for you so you can read them if you really want it supports all the

00:00:56.680 --> 00:01:03.559
usual raid levels and all the usual monitor ing

00:01:01.399 --> 00:01:07.960
Etc things that you might need we've got support for all the latest operating

00:01:05.159 --> 00:01:12.640
systems and you can always of course haha how often do I say this download

00:01:10.439 --> 00:01:17.720
the latest drivers from the manufacturer website thank you LSI for mentioning

00:01:15.159 --> 00:01:21.640
that you've got uh there's calling out that they are the most trusted raid for

00:01:19.200 --> 00:01:25.360
critical data okay they've also got Advanced raid management software and

00:01:24.000 --> 00:01:29.960
they're just talking a little bit about that on the box but what I am most

00:01:27.640 --> 00:01:36.560
interested in about this particular product is coming up

00:01:32.520 --> 00:01:38.799
shortly that was a teaser that's uh

00:01:36.560 --> 00:01:43.600
something that I use from time to time to get people to keep watching the video

00:01:41.280 --> 00:01:47.000
even when it's a product that probably doesn't have a whole lot of implications

00:01:45.360 --> 00:01:51.799
for the average consumer maybe you'll learn a little bit

00:01:49.000 --> 00:01:57.079
of something about raid during this video probably not I do have some more

00:01:54.719 --> 00:02:01.600
raid themed videos upcoming everyone's been bothering me about that and they

00:01:58.799 --> 00:02:05.360
are coming trust me me it's just been uh it's been a little bit hectic and

00:02:03.799 --> 00:02:09.200
there's there's a lot that I want to do with those particular videos so the

00:02:07.240 --> 00:02:13.720
first thing we find inside is what appears to be a quick installation guide

00:02:11.000 --> 00:02:18.480
check that out unpack step one unpack the RAID controller nice okay step two

00:02:16.840 --> 00:02:22.680
prepare the computer by turning it off unplugging the power step three review

00:02:20.400 --> 00:02:25.480
the jumpers and connectors and how much further does this go wow quite a few

00:02:24.000 --> 00:02:31.160
steps so this is quite detailed it includes some um picture diagrams it

00:02:28.920 --> 00:02:34.200
includes a whole bunch of steps and hey look at that it talks about raid so if

00:02:32.440 --> 00:02:38.360
you want to know what raid is you could freeze the video right now and read that

00:02:36.680 --> 00:02:42.360
uh otherwise you can stay tuned for when I'll be doing a video shortly all right

00:02:40.959 --> 00:02:48.560
they've got a technical support number on the back and there's some more raid levels in case you were wondering about

00:02:45.680 --> 00:02:53.920
that there we go okay next we have replacing the full profile bracket with

00:02:50.640 --> 00:02:57.959
low profile brackets how to do it okay

00:02:53.920 --> 00:03:00.200
next we have a uh reduction of hazardous

00:02:57.959 --> 00:03:05.440
substances uh report say saying that this one is okay so it is Ros compliant

00:03:04.000 --> 00:03:10.040
we've got the card itself we'll have a look at that in a moment and then

00:03:07.799 --> 00:03:13.360
underneath it looks like we have a cable kit so not all raid controllers come

00:03:12.000 --> 00:03:17.200
with cable kits you got to check the part number to see if it's a bare card

00:03:15.480 --> 00:03:21.080
or one that comes with cables it doesn't actually matter cuz you can buy cables

00:03:19.360 --> 00:03:25.440
usually for about the same price as it would cost to buy a drive with a cable

00:03:23.799 --> 00:03:29.760
kit so it's it's up to you which route you

00:03:27.760 --> 00:03:33.280
want to go okay so in terms of access accessories we have the low profile

00:03:31.120 --> 00:03:36.280
adapter as you can see it comes with the full height

00:03:34.360 --> 00:03:40.080
adapter so that's if you're installing it in a one U chassis or anything else

00:03:38.000 --> 00:03:46.360
that would require a low profile adapter we've got a couple of adapters I sff 887

00:03:45.000 --> 00:03:51.640
I believe is what this connector is called although feel free to correct me

00:03:48.400 --> 00:03:56.000
if I'm wrong and then that goes to four

00:03:51.640 --> 00:03:58.000
discreete uh SATA SL SAS cables on the

00:03:56.000 --> 00:04:03.959
other side so we have two of those because this is an8 p card next we have

00:04:01.280 --> 00:04:07.120
a driver utilities and documentation DVD so you might not want to throw this

00:04:05.439 --> 00:04:12.560
particular DVD away because it does have some documentation on it um probably how

00:04:10.400 --> 00:04:17.760
to use their software and a bunch of stuff along those lines next we have the

00:04:15.159 --> 00:04:17.760
card

00:04:19.000 --> 00:04:24.120
itself here we have it so these

00:04:22.079 --> 00:04:29.160
interfaces are actually in a rather peculiar place on this card so they plug

00:04:26.280 --> 00:04:34.160
in right here one two and then out of there you're going to be able to plug

00:04:30.680 --> 00:04:36.440
into eight drives directly or you can

00:04:34.160 --> 00:04:40.960
actually use uh Splitters in order to plug this particular card into up to

00:04:39.440 --> 00:04:48.240
shoot I don't know if it says that on the box but up to 32 SAS or SATA devices there

00:04:45.759 --> 00:04:52.880
you go so you can split each so we've got 8 * 32 so you can split each one of

00:04:50.639 --> 00:04:56.240
these connectors four ways if you're using magnetic drives that probably

00:04:54.479 --> 00:05:00.199
makes a lot of sense but if you're going to be doing what I'm going to be doing

00:04:58.160 --> 00:05:03.960
with this card it probably doesn't make much sense because we're going to be

00:05:01.440 --> 00:05:14.080
trying to find the absolute limit in thorough put for this card with drum

00:05:09.280 --> 00:05:16.360
roll8 SSD drive so the Onyx series SSD

00:05:14.080 --> 00:05:20.400
drive that I unboxed recently I have eight of these and I'm going to be

00:05:17.960 --> 00:05:24.319
hooking them all up to this particular RAID controller to see what kind of

00:05:22.400 --> 00:05:28.080
numbers we can pull through it I also have a battery backup unit so battery

00:05:26.759 --> 00:05:32.680
backups actually here this is going to be a little lesson on raid battery

00:05:30.000 --> 00:05:37.680
backups are extremely important because the RAID controller actually uses

00:05:35.000 --> 00:05:42.000
onboard memory in this case 512 Megs of onboard memory so you can see those

00:05:39.720 --> 00:05:49.759
modules are here and there are none on the back to to as a cache so when with a

00:05:46.600 --> 00:05:51.800
normal Drive cache any data that's being

00:05:49.759 --> 00:05:57.199
held in the cache if the system is powered off or um basically if if the

00:05:55.000 --> 00:06:02.360
system loses power for any reason is potentially lost if it's waiting to be

00:05:59.680 --> 00:06:07.639
written to the drives and because these dedicated raid controllers have such

00:06:04.919 --> 00:06:13.360
enormous caches compared to a typical hard drive where you might see a 32 to

00:06:09.840 --> 00:06:16.880
64 Meg cache uh being uh pretty much on

00:06:13.360 --> 00:06:19.880
the high end of what you'd see well it's

00:06:16.880 --> 00:06:21.759
it's a lot more dangerous to have so

00:06:19.880 --> 00:06:25.560
much more data just sitting in a cache waiting to be written when the system's

00:06:23.280 --> 00:06:30.199
powered off so what a battery backup does is it actually provides power to

00:06:28.319 --> 00:06:34.880
the caches in the event that the system loses power and what that does is it

00:06:32.400 --> 00:06:39.199
allows the data to stay there until it can be written to the drives when the

00:06:36.800 --> 00:06:43.599
system is powered back on this is especially important for anything that

00:06:41.039 --> 00:06:48.319
is Mission critical which is typically where you'd be looking at using

00:06:45.240 --> 00:06:50.000
something like a uh high-end raid card

00:06:48.319 --> 00:06:57.039
like this well thank you for checking out my unboxing and first look at the

00:06:52.280 --> 00:06:58.960
LSI Mega raid SAS 9268 I and hopefully I

00:06:57.039 --> 00:07:06.919
will have some very cool videos for you shortly showing off the SSD capabilities

00:07:02.639 --> 00:07:06.919
of this particular card
